Lightning Protector
nominal voltage of a system Un |
continuous-running voltage Uc |
nominal discharge current In |
Nominal discharge residual voltage of Up |
peak current Ihc |
1500 VDC |
2000 VDC |
10kA 8/20 μs |
4.76kV |
100 k 4/10 μs |
Rated voltage equal to operating line conditions (IEC 60850) |
EN 50526-1: 2012,4.1: IEC 60850 1.5kV System Umax2 (1950V) |
EN 50526-1:2012, Table 1: Mine Arrester Class DC-B |
EN 50526-3:2012,6.5 The margin between the residual pressure and the rated impact voltage is generally considered. The rated impact voltage of 1.5kV system and OCS connection equipment is 10kV (EN 50124-1, OV3, Table D-1 and Table A-2). Impact voltage> K * residual voltage (K=1.25~1.4), that is, the residual voltage needs to be less than 7.14kV. |
EN 50526-1:2012, Table 7: Mine Arrester Class DC-B |