  • 避雷针1(1).jpg

Lightning Protector

Protect the DC supply grid overvoltage, can effectively prevent the overvoltage from outside the vehicle (such as lightning strike) and the operating overvoltage inside the vehicle to the vehicle electrical equipment insulation damage.


Detailed introduction

nominal voltage of a system Un

continuous-running voltage Uc

nominal discharge current In

Nominal discharge residual voltage of Up

peak current Ihc

1500 VDC

2000 VDC

10kA 8/20 μs

4.76kV

100 k 4/10 μs

Rated voltage equal to operating line conditions (IEC 60850)

EN 50526-1: 2012,4.1:

 IEC 60850 1.5kV System Umax2 (1950V)

EN 50526-1:2012, Table 1:

Mine Arrester Class DC-B

EN 50526-3:2012,6.5

The margin between the residual pressure and the rated impact voltage is generally considered.

The rated impact voltage of 1.5kV system and OCS connection equipment is 10kV (EN 50124-1, OV3, Table D-1 and Table A-2).

Impact voltage> K * residual voltage (K=1.25~1.4), that is, the residual voltage needs to be less than 7.14kV.

EN 50526-1:2012, Table 7:

Mine Arrester Class DC-B